Gas Burner Installation & Certification Guide

⚠️ MANDATORY PROFESSIONAL INSTALLATION REQUIRED

This page outlines the essential legal and safety requirements for installing your ARGHERI Gas Burner Kit in Australia. The installation of this appliance is NOT a DIY task.


1. Supply Only: Exclusions and Scope

The price you pay for your Argheri Oven and/or Modular Fire Gas Burner Kit is a supply-only price.

What's Included:

  • Oven: Custom, high-thermal-mass masonry structure
  • Gas Burner: Supplied as a separate, loose component

EXCLUDED COSTS: The following professional services are NOT included in the purchase price and must be quoted and paid for separately:

  • Installation, assembly, and commissioning of the burner into the oven
  • Running gas lines and connection to main supply
  • Electrical supply installation (for E/T Series burners)
  • Mandatory Type B Certification
  • Compliance Certificate issuance

These services must be provided by a licensed gas contractor.


2. Type A vs. Type B Appliance: Understanding the Key Difference

In Australia, gas appliances are classified into two categories that determine the certification process:

Type A Appliances (Mass Produced)

Definition: Standardised, mass-produced appliances for residential and light commercial use

Examples: Residential gas stoves, standard BBQs, patio heaters

Certification: Pre-certified by bodies like the Australian Gas Association (AGA) with approval badges. Installation completed by a standard licensed Type A gas fitter who issues a certificate of compliance for the piping work.

Type B Appliances (Commercial/Industrial)

Definition: Non-standard, large commercial, or industrial appliances with gas consumption typically exceeding 10 MJ/h. This includes appliances that are custom-built or assembled in-situ.

Certification: Requires individual assessment and certification after installation to ensure the combined assembly meets AS 3814 standards: Industrial and commercial gas-fired appliances.


3. Why Your ARGHERI Oven Requires Type B Certification

ARGHERI ovens are not mass-produced appliances. Each oven is a custom build tailored specifically for the individual customer.

Because of this:

  • The gas burner is supplied separately from the oven structure
  • The burner must be installed in-situ (on-site) under the oven or bench
  • The combined assembly (oven + burner + flue system) creates a unique installation
  • All ARGHERI burners exceed the 10 MJ/h threshold for Type B classification

Therefore: The entire installation must be treated as a Type B Appliance installation and requires Type B Certification.


4. The Mandatory Certification Process

What is Type B Certification?

You must engage a licensed Type B Gas Certifier or authorised Type B Gas Fitter to oversee installation and certify the final appliance.

The Process:

Step 1: Technical Submission Before installation, the Certifier or Fitter reviews:

  • Burner technical specifications
  • Proposed installation design
  • Compliance with AS 3814 standards

Step 2: Installation The licensed professional installs:

  • Gas burner unit under the oven or bench
  • Gas supply lines and connections
  • Electrical connections (if required for E/T Series)
  • Flue system integration

Step 3: Commissioning After installation, the Certifier conducts an on-site inspection testing:

  • Burner operation and safety controls
  • Flue integrity and ventilation
  • Gas pressure and leak testing
  • Compliance with AS 3814 standards

Step 4: Final Certification If compliant, the Certifier:

  • Issues a Type B Certificate of Compliance
  • Affixes a certification label to the appliance
  • Submits documentation to the relevant state authority

⚠️ CRITICAL REQUIREMENT

YOU MUST NOT OPERATE THE GAS BURNER UNTIL THE CERTIFICATE IS ISSUED.

Failure to obtain proper certification will:

  • Void your warranty
  • Create serious safety risks
  • Violate legal requirements

5. State-Based Governing Bodies (Technical Regulators)

While Type B Certifiers can operate across state borders, each state has its own primary gas safety regulatory body:

State/Territory Governing Body Website
New South Wales (NSW) NSW Fair Trading fairtrading.nsw.gov.au
Victoria (VIC) Energy Safe Victoria (ESV) energysafe.vic.gov.au
Queensland (QLD) Resources Safety and Health Queensland (RSHQ) rshq.qld.gov.au
South Australia (SA) Office of the Technical Regulator (OTR) energymining.sa.gov.au
Western Australia (WA) Building and Energy / DMIRS demirs.wa.gov.au
Tasmania (TAS) Consumer, Building and Occupational Services (CBOS) cbos.tas.gov.au
Australian Capital Territory (ACT) Access Canberra accesscanberra.act.gov.au
Northern Territory (NT) NT WorkSafe worksafe.nt.gov.au

 

Your Type B Certifier will handle the submission of compliance documentation to the appropriate authority in your state or territory.


6. Your Next Steps

Finding a Qualified Professional

Search for:

  • Type B Gas Fitter
  • Type B Gas Certifier
  • Commercial Gas Fitter
  • Combustion Engineer

Important: Not all standard gas fitters are authorised to work on Type B appliances. Verify their Type B certification before engaging their services.

Getting Quotes

Provide the fitter with:

  • Burner model (M-Series or E/T-Series)
  • Burner kW rating (14 kW or 34 kW)
  • Oven model (Forzo 70/100/120/Pro)
  • Installation location and gas supply type (LPG or Natural Gas)

Expected costs typically range from $900 to $2,500 AUD depending on:

  • Location and accessibility
  • Complexity of gas line installation
  • Electrical requirements (E/T Series)
  • Additional ventilation or flue modifications

Documentation to Retain

After installation, ensure you receive:

  • Type B Certificate of Compliance – Your proof of legal, safe installation
  • Compliance Certificate submission receipt – Confirmation it's been lodged with your state authority
  • Warranty activation documentation – Required to validate your ARGHERI warranty

7. Safety and Legal Compliance

Australian Standards Compliance

All installations must comply with:

  • AS 3814 – Industrial and commercial gas-fired appliances
  • AS 5601 – Gas installations
  • AS 1668 – Mechanical ventilation and air-conditioning

Flue Requirements

A properly installed and certified flue system is mandatory to:

  • Safely vent exhaust gases
  • Ensure adequate ventilation
  • Prevent carbon monoxide buildup
  • Meet building and fire safety codes

Ventilation Requirements

The installation area must meet local codes for:

  • Fresh air supply
  • Exhaust ventilation
  • Cross-ventilation (for covered outdoor areas)

Need Burner Specifications or Technical Support?

Contact the ARGHERI support team for:

  • Recommended:
    • Type B Gas fitters in your area
    • Type B Gas Certifiers in your area
  • Detailed burner specifications for your fitter
  • Technical installation guidance
  • Product inquiries